LP415 UV Block A/R Protective Window

UV Block A/R Protective Window for machine-vision imaging — passes 415-1100nm and blocks out-of-band light for repeatable contrast on the line.

Overview [ 01 ]

UV Block A/R Protective Window

Specifications [ 02 ]
Useful range415-1100nm
Wavelength bandVisible
Cut-on (50%)415nm
Min peak transmission≥95%
Tolerance+/- 10nm
Surface quality40/20
Mount & Size [ 03 ]
25.4® C-Mount
mm

Enter your lens part number to get the right filter size.

nmT %
110087.60
109087.97
108088.34
107088.63
106088.85
105088.98
104089.02
103089.01
102088.93
101088.79
100088.59
99088.43
98088.25
97088.10
96088.02
95088.02
94088.13
93088.34
92088.72
91089.23
90089.88
89090.65
88091.55
87092.79
nmT %
86093.94
85094.77
84095.54
83096.26
82096.82
81097.15
80097.29
79097.24
78097.00
77096.73
76096.44
75096.19
74096.09
73096.35
72096.74
71097.47
70098.06
69098.76
68099.32
67099.48
66099.20
65098.85
64098.32
63097.91
nmT %
62097.75
61097.96
60098.31
59098.72
58098.79
57098.48
56098.03
55097.63
54097.92
53098.79
52099.40
51098.82
50096.90
49095.04
48095.14
47097.05
46098.22
45097.57
44097.60
43097.41
42092.03
41033.28
4002.79
3900.25
nmT %
3800.04
3700.01
3600.01
3500.00
3400.00
3300.00
3200.01
3100.00
3000.00
2900.00
2800.00
2700.00
2600.00
2500.00
2400.00
2300.00
2200.00
2100.01
2000.01